A steel plate girder is subjected to a maximum factored shear force of 2800 kN. The cross-section of the girder is shown in the figure. Design a suitable fillet weld to connect flange plates to the web. Assume shop welding. E250 grade of steel having f_u = 410 MPa is used. Use limit state method of design. Take γ_mw = 1·25 :
[Figure, described in words: a welded I-section with top and bottom flange plates each 650 mm wide × 25 mm thick, and a web plate 1500 mm deep × 15 mm thick between the flanges; each flange is connected to the web by fillet welds on both sides of the web.]
10 marks · directive: Design
The core of a good answer
The horizontal shear flow at the flange to web junction is about 1501 N/mm, which needs a 5.7 mm fillet on each side; provide 6 mm continuous shop fillet welds on both sides of the web at each flange (capacity 1591 N/mm), which also satisfies the IS 800 minimum size for a 25 mm thick part.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
The welds between flange and web must transfer the longitudinal (horizontal) shear flow q = VAȳ/I. The design requires the section's second moment of area, the first moment of one flange about the neutral axis, the design strength of a fillet weld per IS 800:2007 and a check against minimum and maximum weld sizes.
Answer outline
Introduction
V = 2800 kN (factored); flange 650 × 25 mm, web 1500 × 15 mm; f_u = 410 MPa; γ_mw = 1.25 (shop weld). Two fillet welds (one each side of the web) at each flange.
Step 1: Second moment of area
- I = 15 × 1500³/12 + 2[650 × 25³/12 + 650 × 25 × (750 + 12.5)²]
- I = 4.219×10⁹ + 2(8.46×10⁵ + 9.448×10⁹) = 2.3116×10¹⁰ mm⁴
Step 2: Shear flow at the flange to web junction
- Aȳ of one flange = 650 × 25 × 762.5 = 1.2391×10⁷ mm³
- q = VAȳ/I = 2800×10³ × 1.2391×10⁷/2.3116×10¹⁰ = 1500.8 N/mm
Step 3: Design strength of the weld
- f_wd = f_u/(√3 γ_mw) = 410/(√3 × 1.25) = 189.4 MPa
- Strength of two welds of size s per mm = 2 × 0.7s × 189.4 = 265.1s N/mm
Step 4: Weld size
- 265.1s ≥ 1500.8 gives s ≥ 5.66 mm
- Minimum size for thicker part 25 mm (over 20 up to 32 mm) = 6 mm (IS 800 Table 21)
- Provide s = 6 mm; throat = 0.7 × 6 = 4.2 mm
- Capacity = 2 × 4.2 × 189.4 = 1590.7 N/mm > 1500.8 N/mm, safe
Step 5: Detailing
- 6 mm continuous fillet weld on both sides of the web at top and bottom flanges, shop welded.
- Throat 4.2 mm ≤ 0.7 × 15 = 10.5 mm (IS 800 cl. 10.5.3.1), so the upper limit is satisfied.
Conclusion
Adopt 6 mm continuous fillet welds on each side of the web at both flanges; utilisation 1500.8/1590.7 ≈ 0.94.
Examples and data to cite
- IS 800:2007 cl. 10.5.3.1: the effective throat of a fillet weld shall not be less than 3 mm and shall generally not exceed 0.7t (t = thinner plate); here 4.2 mm ≤ 0.7 × 15 = 10.5 mm.
- If site welding had been specified, γ_mw would change and the same shear flow would need a proportionally larger weld; the question fixes γ_mw = 1.25 for shop welding.
Facts to remember
- Shear flow q = VQ/I, with Q the first moment about the neutral axis of the area beyond the section considered.
- IS 800:2007 cl. 10.5.7.1.1: f_wd = f_u/(√3 γ_mw), f_u the smaller of weld and parent metal; effective throat = 0.70 × size for a 60° to 90° fillet (Table 22).
- γ_mw = 1.25 is given in the question for shop welding.
- IS 800:2007 Table 21 sets the minimum fillet size from the thickness of the thicker part (6 mm for over 20 up to 32 mm).