A vertical member in a truss is subjected to the following member force (factored) :
(i) Compressive force = 30 kN (dead and live load)
(ii) Tensile force = 150 kN (dead and wind load)
The member is composed of two numbers ISA 100 × 100 × 8 connected to both sides of the gusset plate of thickness 10 mm. Find the number of bolts required at the joint. Assume bolt diameter = 16 mm, grade of bolt = 4·6, γ_mb = 1·25, k_b = 0·6, cross-sectional area at the threaded part of the bolt = 0·78 times that of shank. Use limit state method of design.
10 marks · directive: Find
The core of a good answer
The bolts are in double shear with a design value of about 57.9 kN (threads in both shear planes, governing over bearing 78.7 kN); for the larger force of 150 kN, 150/57.9 = 2.59, so 3 bolts of 16 mm grade 4.6 are required.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
A bearing type bolted connection design under IS 800:2007. Because the angles sit on both sides of the gusset, each bolt is in double shear; bearing is checked on the thinner of the gusset (10 mm) and the two angle legs (2 × 8 = 16 mm). The connection is designed for the larger of the reversing forces.
Answer outline
Introduction
d = 16 mm, f_ub = 400 MPa (grade 4.6), f_u (plate) = 410 MPa (E250, as printed in Q1(e); assumed), γ_mb = 1.25, k_b = 0.6. A_sb = π × 16²/4 = 201.1 mm²; A_nb = 0.78 × 201.1 = 156.8 mm².
Step 1: Design force
- Design for the larger of 150 kN (tension) and 30 kN (compression): 150 kN
- Load reversal means bolts must work in both directions; bearing type bolts do.
Step 2: Shear capacity (double shear)
- V_dsb = f_ub(n_n A_nb + n_s A_sb)/(√3 γ_mb)
- Conservatively take both shear planes through threads: n_n = 2, n_s = 0
- V_dsb = 400 × 2 × 156.8/(√3 × 1.25) = 57.95 kN
- (If one plane passes through the shank: 66.12 kN; the conservative value is used.)
Step 3: Bearing capacity
- Thickness in bearing = min(10, 2 × 8) = 10 mm (gusset)
- V_dpb = 2.5 k_b d t f_u/γ_mb = 2.5 × 0.6 × 16 × 10 × 410/1.25 = 78.72 kN
Step 4: Bolt value and number
- Bolt value = min(57.95, 78.72) = 57.95 kN
- n = 150/57.95 = 2.59, provide 3 bolts
Step 5: Detailing notes
- Pitch ≥ 2.5d = 40 mm (IS 800 cl. 10.2.2); edge distance ≥ 1.7 × hole diameter for sheared or hand flame cut edges or 1.5 × for rolled, machine flame cut, sawn or planed edges (cl. 10.2.4.2), with an 18 mm standard hole (Table 19); one line of bolts on the 100 mm legs.
Conclusion
Provide 3 bolts of 16 mm diameter, grade 4.6, in double shear; capacity 3 × 57.95 = 173.8 kN > 150 kN.
Examples and data to cite
- IS 800 cl. 10.3.3 distinguishes shear planes with threads (n_n, area A_nb) and without threads (n_s, area A_sb); assuming threads in both planes, as here, gives the lower and safe bolt value.
- Because the member force reverses (150 kN tension, 30 kN compression), the connection is designed for the larger magnitude; bearing type bolts resist load in either direction.
Facts to remember
- IS 800:2007 cl. 10.3.3: V_dsb = f_ub(n_n A_nb + n_s A_sb)/(√3 γ_mb).
- IS 800:2007 cl. 10.3.4: V_dpb = 2.5 k_b d t f_u/γ_mb, with t = summation of thicknesses of the connected plates bearing in the same direction (the smaller sum governs) and f_u of the plate.
- Property class 4.6 bolt: ultimate tensile strength 400 MPa and yield strength 0.6 × 400 = 240 MPa.
- Bolt value = lesser of shear and bearing strengths; number of bolts = design force/bolt value, rounded up.