A simply supported beam ISMB 400 @ 61·6 kg/m has an effective span of 5 m. Find the design bending strength of the beam and the intensity of u.d.l. that the beam can carry under service condition. Assume that the beam is laterally supported. The grade of the steel is E250. The class of section is plastic. For ISMB 400, I_zz = 20458 cm⁴, Z_ez = 1023 cm³, Z_pz = 1176 cm³. Assume γ_m0 = 1·1. Use limit state method of design.
10 marks · directive: Find
The core of a good answer
Design bending strength M_d = Z_p f_y/γ_m0 = 267.3 kN·m (below the 1.2Z_e f_y/γ_m0 cap of 279.0 kN·m); the factored u.d.l. is 85.5 kN/m, so the service u.d.l. is about 57.0 kN/m in total (about 56.4 kN/m besides self-weight), with low shear and deflection within the IS 800 limits.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
A laterally supported beam under IS 800:2007 clause 8.2.1.2. The plastic section has β_b = 1, and the capacity is capped at 1.2Z_e f_y/γ_m0 for simply supported beams. The service load is the factored load divided by the load factor 1.5; good answers also check shear and deflection.
Answer outline
Introduction
ISMB 400, E250 (f_y = 250 MPa), L = 5 m, Z_p = 1176×10³ mm³, Z_e = 1023×10³ mm³, I = 20458×10⁴ mm⁴, γ_m0 = 1.1, self-weight 61.6 kg/m = 0.604 kN/m.
Step 1: Design bending strength
- M_d = β_b Z_p f_y/γ_m0 = 1.0 × 1176×10³ × 250/1.1 = 267.27 kN·m
- Limit: 1.2 Z_e f_y/γ_m0 = 1.2 × 1023×10³ × 250/1.1 = 279.0 kN·m
- M_d = 267.27 kN·m (governs)
Step 2: Factored and service u.d.l.
- w_u L²/8 = M_d gives w_u = 8 × 267.27/5² = 85.53 kN/m
- Service u.d.l. w = 85.53/1.5 = 57.02 kN/m (total)
- Excluding self-weight 0.604 kN/m: imposed u.d.l. ≈ 56.41 kN/m
Step 3: Shear check
- V_u = 85.53 × 5/2 = 213.8 kN
- V_d = h t_w f_y/(√3 γ_m0) = 400 × 8.9 × 250/(√3 × 1.1) = 467.1 kN (t_w = 8.9 mm, IS 808:1989 table for MB 400; A_v = h t_w for hot rolled I-sections in major axis bending, IS 800 cl. 8.4.1.1)
- V_u < 0.6V_d = 280.3 kN: low shear, no reduction in M_d
Step 4: Deflection check (service load)
- δ = 5wL⁴/(384EI) = 5 × 57.02 × 5000⁴/(384 × 2×10⁵ (E for steel, IS 800 cl. 2.2.4.1) × 20458×10⁴) = 11.34 mm
- Even under the total service load this is below span/300 = 16.67 mm and span/360 = 13.89 mm (IS 800 Table 6 limits), so deflection is satisfied
Conclusion
M_d = 267.3 kN·m; safe service u.d.l. ≈ 57.0 kN/m (total). Strength governs, not deflection or shear.
Examples and data to cite
- IS 800 cl. 3.7.2 defines a plastic (Class 1) section as one that can develop plastic hinges and has the rotation capacity required for failure of the structure by formation of a plastic mechanism, which is why the full Z_p is used.
- The 1.2 Z_e f_y/γ_m0 cap (279.0 kN·m) does not govern here because Z_p/Z_e = 1.15 < 1.2.
Facts to remember
- IS 800:2007 cl. 8.2.1.2: M_d = β_b Z_p f_y/γ_m0 ≤ 1.2 Z_e f_y/γ_m0 (simply supported), β_b = 1 for plastic and compact sections.
- IS 800 cl. 8.2.1.2 applies when the factored shear does not exceed 0.6V_d (low shear); cl. 8.4.1.1 takes A_v = h t_w for hot rolled I-sections bent about the major axis.
- IS 800 Table 4: partial safety factor 1.5 for dead plus live load at the limit state of strength.
- Maximum moment for a simply supported u.d.l.: wL²/8; central deflection 5wL⁴/(384EI).