Oil of specific gravity of 0.8 and kinematic viscosity of 1.5×10⁻⁴ m²/s is pumped at a rate of 0.015 m³/s through a 150 mm diameter, 325 m long pipe. Determine the Reynolds' number, pressure drop, average shear stress at the pipe wall and power required to maintain flow under the following conditions :
(i) If the pipe is horizontal
(ii) If the pipe is inclined at 10° with the horizontal and the flow is in the upward direction
20 marks · directive: Determine
The core of a good answer
Re = 849 (laminar); horizontal pipe: Δp = 47.1 kPa, wall shear stress 5.43 Pa, power 706 W; pipe inclined 10° upward: Δp = 47.1 + 442.9 = 490.0 kPa, wall shear stress still 5.43 Pa, power 7.35 kW.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
The question tests laminar pipe flow (Hagen Poiseuille) and the force balance on a pipe element. The Reynolds number decides the regime; the frictional pressure drop and wall shear depend only on the flow, while inclining the pipe adds the hydrostatic lift ρgL sinθ to the pressure drop and to the pumping power.
Answer outline
Introduction
Given: SG = 0.8 so ρ = 800 kg/m³, ν = 1.5 × 10⁻⁴ m²/s, μ = ρν = 0.12 Pa s, Q = 0.015 m³/s, D = 0.15 m, L = 325 m, θ = 10°.
Step 1: Velocity and Reynolds number
- A = π × 0.15²/4 = 0.017671 m²
- V = Q/A = 0.015/0.017671 = 0.8488 m/s
- Re = VD/ν = 0.8488 × 0.15/1.5 × 10⁻⁴ = 848.8 < 2000, so the flow is laminar
Step 2: Frictional pressure drop (horizontal)
- Δp = 32μVL/D² = 32 × 0.12 × 0.8488 × 325/0.0225 = 47,082 Pa ≈ 47.1 kPa
- Check with Darcy: f = 64/Re = 0.0754; hf = fLV²/(2gD) = 6.00 m of oil; ρghf = 800 × 9.81 × 6.00 = 47.1 kPa
Step 3: Wall shear stress
- Force balance: Δp (πD²/4) = τw (πDL), so τw = Δp D/(4L)
- τw = 47,082 × 0.15/(4 × 325) = 5.43 Pa
Step 4: Power (horizontal)
- P = Δp × Q = 47,082 × 0.015 = 706 W
Step 5: Inclined pipe, flow upward at 10°
- Elevation rise Δz = L sin10° = 325 × 0.17365 = 56.44 m
- Additional pressure = ρgΔz = 800 × 9.81 × 56.44 = 442,907 Pa
- Δp = 47,082 + 442,907 = 489,989 Pa ≈ 490.0 kPa
- Wall shear stress is unchanged, τw = 5.43 Pa (it depends on frictional loss only; Re also unchanged at 849)
- P = Δp × Q = 489,989 × 0.015 = 7,350 W ≈ 7.35 kW
Conclusion
(i) Re 849, Δp 47.1 kPa, τw 5.43 Pa, P 0.71 kW; (ii) Re 849, Δp 490 kPa, τw 5.43 Pa, P 7.35 kW. Most of the power in case (ii) is spent lifting the oil, not overcoming friction.
Examples and data to cite
- For the same flow, the elevation term makes pumping uphill about ten times costlier here than pumping on level ground.
Facts to remember
- Hagen Poiseuille law: Δp = 32μLV/D² for fully developed laminar flow; Darcy friction factor f = 64/Re.
- Laminar flow in pipes for Re below about 2000.
- Wall shear stress τw = Δp D/(4L) from a force balance; maximum velocity in laminar flow = 2V.
- Pumping power = Δp Q (or ρgQ × total head).