Consider a thermoelectric power plant of 1000 Mega Watt capacity with a load factor of 70 percent and an efficiency of 42 percent. Determine pollutants emitted on an annual basis such as particulates, carbon dioxide, and sulphur dioxide, if coal is used as fuel.
The ultimate analysis and calorific value of the coal used are as follows :
Moisture | Ash | Carbon | Hydrogen | Nitrogen | Sulphur
8% | 7% | 78% | 2% | 2% | 1%
Oxygen | Calorific Value | Fly ash
2% | 30 Mega Joules/kg | 77% of ash
Assume complete combustion as per the stoichiometric equation and no air pollution control device.
If an electrostatic precipitator is installed which removes 99% of particulates, compute the amount of particulate emissions.
15 marks · directive: Calculate
The core of a good answer
The plant burns 1.752 million tonnes of coal a year and, without controls, emits about 94,400 t of particulates (fly ash), 5.01 million t of CO₂ and 35,040 t of SO₂ per year; with a 99% efficient ESP, particulate emission falls to about 944 t per year.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
Energy balance gives the coal burnt; the ultimate analysis and stoichiometry (C + O₂ → CO₂, S + O₂ → SO₂) give the gases; fly ash fraction of ash gives particulates.
Answer outline
Introduction
Capacity 1000 MW, load factor 0.70, efficiency 0.42, calorific value 30 MJ/kg; carbon 78%, sulphur 1%, ash 7% with 77% leaving as fly ash.
Step 1: Electrical energy produced per year
- E = 1000 MW × 0.70 × 8760 h = 6.132 × 10⁶ MWh
- E = 6.132 × 10⁶ × 3.6 × 10⁹ J = 2.2075 × 10¹⁶ J
Step 2: Heat input and coal burnt
- Heat input = 2.2075 × 10¹⁶/0.42 = 5.256 × 10¹⁶ J
- Coal = 5.256 × 10¹⁶/(30 × 10⁶ J/kg) = 1.752 × 10⁹ kg = 1.752 million t/year (4800 t/day)
Step 3: Particulates (no control)
- Ash = 0.07 × 1.752 × 10⁹ = 1.2264 × 10⁸ kg
- Fly ash = 0.77 × 1.2264 × 10⁸ = 9.443 × 10⁷ kg ≈ 94,433 t/year (bottom ash ≈ 28,207 t is removed from the bottom of the boiler)
Step 4: Carbon dioxide
- C + O₂ → CO₂: 12 kg C gives 44 kg CO₂
- CO₂ = 0.78 × 1.752 × 10⁹ × 44/12 = 5.011 × 10⁹ kg ≈ 5.01 million t/year
Step 5: Sulphur dioxide
- S + O₂ → SO₂: 32 kg S gives 64 kg SO₂
- SO₂ = 0.01 × 1.752 × 10⁹ × 2 = 3.504 × 10⁷ kg = 35,040 t/year
Step 6: With a 99% electrostatic precipitator
- Particulates emitted = 0.01 × 94,433 = 944 t/year (about 2.6 t/day)
Conclusion
Annual emissions: particulates ≈ 94,400 t (944 t with ESP), CO₂ ≈ 5.01 Mt, SO₂ ≈ 35,000 t. Check: CO₂ intensity = 5.011 × 10⁹ kg/6.132 × 10⁹ kWh ≈ 0.82 kg/kWh.
Examples and data to cite
- ESP efficiency is decisive: at 99.9% the same plant would emit about 94 t of particulates a year instead of 944 t.
Facts to remember
- Annual energy = capacity × load factor × 8760 h.
- Fuel mass = energy output/(efficiency × calorific value).
- C → CO₂ multiplies mass by 44/12; S → SO₂ multiplies by 64/32 = 2.
- Fly ash is generally captured by electrostatic precipitators before flue gas reaches the chimney.