Pratidin
2026 · Electrical Engineering Optional Paper I · 10 marksMainsQuestion 3c

The outer diameter of the inner conductor and the inner diameter of the outer conductor of a coaxial copper transmission line are 2 mm and 7 mm, respectively. Both the conductors have thickness much greater than the skin depth. The dielectric is lossless and the operating frequency is 400 MHz. Calculate the resistance per meter length of the transmission line. The resistivity and relative permeability of the copper are approximately ρ = 1·724 × 10⁻⁸ Ω-m and 1, respectively.

10 marks · directive: Calculate

Answer

The core of a good answer

At 400 MHz the skin depth in copper is about 3.30 μm and the surface resistance R_s = √(πfμρ) ≈ 5.22 mΩ, so R = (R_s/2π)(1/a + 1/b) with a = 1 mm, b = 3.5 mm gives about 0.830 + 0.237 ≈ 1.07 Ω/m.

An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work

What the question asks

A skin effect problem: at high frequency current flows in a thin layer of thickness δ on the facing surfaces of the two conductors (outer surface of the inner conductor and inner surface of the outer conductor), so each conductor's resistance is R_s divided by its circumference.

Answer outline

Introduction

a = 2/2 = 1 mm (inner conductor radius), b = 7/2 = 3.5 mm (inner radius of outer conductor), f = 400 MHz, ρ = 1.724 × 10⁻⁸ Ω m, μ = μ₀ = 4π × 10⁻⁷ H/m.

Step 1: Skin depth

Step 2: Surface resistance

Step 3: Resistance of each conductor per metre

Step 4: Total series resistance per metre

Step 5: Comparison

Conclusion

R ≈ 1.07 Ω per metre; the inner conductor contributes about 78% because its circumference is smaller.

Examples and data to cite

Facts

Facts to remember

Sources used for the explanation

Write a timed answer in the app