The outer diameter of the inner conductor and the inner diameter of the outer conductor of a coaxial copper transmission line are 2 mm and 7 mm, respectively. Both the conductors have thickness much greater than the skin depth. The dielectric is lossless and the operating frequency is 400 MHz. Calculate the resistance per meter length of the transmission line. The resistivity and relative permeability of the copper are approximately ρ = 1·724 × 10⁻⁸ Ω-m and 1, respectively.
10 marks · directive: Calculate
The core of a good answer
At 400 MHz the skin depth in copper is about 3.30 μm and the surface resistance R_s = √(πfμρ) ≈ 5.22 mΩ, so R = (R_s/2π)(1/a + 1/b) with a = 1 mm, b = 3.5 mm gives about 0.830 + 0.237 ≈ 1.07 Ω/m.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
A skin effect problem: at high frequency current flows in a thin layer of thickness δ on the facing surfaces of the two conductors (outer surface of the inner conductor and inner surface of the outer conductor), so each conductor's resistance is R_s divided by its circumference.
Answer outline
Introduction
a = 2/2 = 1 mm (inner conductor radius), b = 7/2 = 3.5 mm (inner radius of outer conductor), f = 400 MHz, ρ = 1.724 × 10⁻⁸ Ω m, μ = μ₀ = 4π × 10⁻⁷ H/m.
Step 1: Skin depth
- δ = √(ρ/(πfμ)) = √(1.724 × 10⁻⁸/(π × 4 × 10⁸ × 4π × 10⁻⁷))
- δ = 3.304 × 10⁻⁶ m ≈ 3.30 μm, much smaller than both conductor thicknesses, as stated
Step 2: Surface resistance
- R_s = ρ/δ = √(πfμρ) = √(π × 4 × 10⁸ × 4π × 10⁻⁷ × 1.724 × 10⁻⁸)
- R_s = 5.218 × 10⁻³ Ω (per square)
Step 3: Resistance of each conductor per metre
- Inner: R_i = R_s/(2πa) = 5.218 × 10⁻³/(2π × 10⁻³) = 0.830 Ω/m
- Outer: R_o = R_s/(2πb) = 5.218 × 10⁻³/(2π × 3.5 × 10⁻³) = 0.237 Ω/m
Step 4: Total series resistance per metre
- R = (R_s/2π)(1/a + 1/b) = 0.830 + 0.237 = 1.068 Ω/m ≈ 1.07 Ω/m
Step 5: Comparison
- DC resistance of the inner conductor alone would be ρ/(πa²) = 1.724 × 10⁻⁸/(π × 10⁻⁶) ≈ 5.5 mΩ/m, so skin effect raises the inner conductor's resistance about 150 times at 400 MHz.
Conclusion
R ≈ 1.07 Ω per metre; the inner conductor contributes about 78% because its circumference is smaller.
Examples and data to cite
- Since R_s = √(πfμρ), the conductor resistance of the line rises with √f; at 100 MHz this line would have half the resistance found here.
- Inner conductors of coaxial cable are sometimes silver plated to reduce losses due to skin effect, since the current flows in a surface layer only a few micrometres thick at such frequencies.
Facts to remember
- Skin depth δ = √(2ρ/(ωμ)) = √(ρ/(πfμ)).
- Surface resistance R_s = ρ/δ = √(πfμρ).
- High frequency resistance of a coaxial line R = (R_s/2π)(1/a + 1/b) Ω/m.
- μ₀ = 4π × 10⁻⁷ H/m.