A three-phase, star-connected, 415 V, 50 Hz, cage-type induction motor takes a starting current equal to 10 times of its no-load current magnitude. The starting torque is one-third (1/3 times) of its pull-out torque (POT), all under rated conditions. The motor takes 300 W input power at 0·2 p.f. lag with rated supply voltage and frequency. Its core loss has no hysteresis component. Find the starting current and input p.f. of the motor at 5 Hz supply voltage maintaining rated V/f ratio. Neglect stator leakage impedance and rotor current at no load. Assume linear magnetic circuit.

20 marks · directive: Find

Answer

The core of a good answer

With stator impedance neglected, T_st/T_max = 2s_m/(1 + s_m²) = 1/3 gives R₂′/X₂′ = s_m = 0·1716; fitting the rated starting current (20·87 A) gives R₂′ = 2·157 Ω and X₂′ = 12·573 Ω, and at 5 Hz with V/f constant (23·96 V per phase) the starting current is about 10·8 A at about 0·77 p.f. lag.

An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work

What the question asks

The problem tests the approximate equivalent circuit with the magnetising branch at the terminals, the torque-slip relation, and how each element changes with frequency under constant V/f: reactances scale with f, rotor resistance does not, magnetising current stays the same and eddy-current loss scales with V². The starting current is taken as the total stator current (rotor plus no-load components).

Answer outline

Introduction

Per phase: V = 415/√3 = 239·60 V. No-load: I₀ = 300/(√3 × 415 × 0·2) = 2·087 A at 0·2 p.f. lag (−78·46°). Rated starting current = 10 × 2·087 = 20·87 A.

Step 1: Rotor R/X ratio from torque data

Step 2: Rotor impedance from starting current

Step 3: Shunt branch at 5 Hz with V/f constant

Step 4: Rotor current at standstill, 5 Hz

Step 5: Starting current and power factor at 5 Hz

Conclusion

At 5 Hz with rated V/f the starting current falls to about 10·8 A (about half of the 50 Hz value) while the starting power factor rises from about 0·17 to about 0·77 lag, because rotor resistance now dominates the rotor reactance.