(i) A single-phase, one-pulse, SCR-controlled converter with R-L-E load has the following data :
Supply voltage V_s = 230 V at 50 Hz, R = 2 Ω, L = 1 mH, E = 120 V, firing angle α = 25° and extinction angle β = 220°
1. Calculate the voltage across the SCR at the instant SCR is triggered.
2. Find the voltage that appears across the SCR when current decays to zero.
3. Find the peak inverse voltage for the SCR.
10 marks · directive: Calculate
The core of a good answer
With V_m = 230√2 = 325·27 V, the SCR voltage is v_s − E: (1) 325·27 sin 25° − 120 = 17·46 V forward at triggering, (2) 325·27 sin 220° − 120 = −329·08 V (reverse) when current falls to zero at β, and (3) PIV = V_m + E = 445·27 V at ωt = 270°.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
In a half-wave controlled rectifier with a back emf load, the SCR voltage when it is not conducting equals v_s − E. The question checks that the candidate applies this at α, at β and at the most negative point of the supply.
Answer outline
Introduction
Given V_s = 230 V rms, so V_m = 230√2 = 325·27 V; E = 120 V; α = 25°; β = 220°. R and L do not affect the SCR voltage while it is off.
Step 1: SCR voltage while off
- When the SCR is not conducting, load current is zero, so no drop in R and L
- v_T = v_s − E = V_m sin ωt − E
Step 2: At the instant of triggering (ωt = α = 25°)
- v_T = 325·27 sin 25° − 120 = 137·46 − 120 = 17·46 V (forward bias, so the SCR can turn on)
- Check: minimum firing angle θ₁ = sin⁻¹(E/V_m) = sin⁻¹(0·369) = 21·65°, and α = 25° > θ₁
Step 3: When current decays to zero (ωt = β = 220°)
- v_T = 325·27 sin 220° − 120 = −209·08 − 120 = −329·08 V
- The SCR is reverse biased by about 329 V just after turn-off
Step 4: Peak inverse voltage
- Reverse voltage is maximum at ωt = 270° (which lies in the off period 220° to 385°)
- PIV = V_m + E = 325·27 + 120 = 445·27 V
Conclusion
The SCR sees 17·46 V forward at firing, 329·08 V reverse at extinction, and a peak inverse voltage of 445·27 V; the device must be rated above this PIV with a safety margin.
Examples and data to cite
- Battery chargers built as single-phase half-wave controlled rectifiers are the usual R-L-E (back emf) load example.
- The extinction angle β > 180° shows the inductance keeps the SCR conducting into the negative half cycle until stored energy is spent.
Facts to remember
- SCR off-state voltage with back emf load: v_T = v_s − E.
- Firing is possible only when V_m sin α > E, i.e. α > sin⁻¹(E/V_m).
- PIV in a half-wave circuit with back emf E: V_m + E.
- Conduction angle = β − α = 195° here.