A unity feedback system has open loop transfer function G(s) = K/(s(s + q)). Evaluate the value of K and q so that settling time and peak overshoot will be 6 seconds and 20% respectively.
10 marks · directive: Evaluate
The core of a good answer
With the 2% settling criterion, ζ = 0.456, ωn = 1.462 rad/s, so q = 2ζωn = 1.333 and K = ωn² = 2.138; if the 5% criterion (ts = 3/ζωn) is used instead, q = 1.0 and K = 1.203.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
This is a standard second-order time-domain design problem. The closed-loop characteristic equation of the unity feedback system is compared with the standard form s² + 2ζωn s + ωn², the damping ratio is found from the peak overshoot and ζωn from the settling time. The candidate must state which settling-time criterion is assumed, since the question does not specify it.
Answer outline
Introduction
Closed-loop transfer function T(s) = G/(1 + G) = K/(s² + q s + K). Given ts = 6 s and Mp = 20% = 0.2. Compare with ωn²/(s² + 2ζωn s + ωn²): ωn² = K and 2ζωn = q.
Step 1: Damping ratio from peak overshoot
- Mp = exp(−ζπ/√(1 − ζ²)) = 0.2
- ζπ/√(1 − ζ²) = −ln 0.2 = 1.6094
- ζ = 1.6094/√(π² + 1.6094²) = 1.6094/3.5299 = 0.4559
Step 2: ζωn from settling time (2% criterion)
- ts = 4/(ζωn) = 6 s
- ζωn = 4/6 = 0.6667 s⁻¹
Step 3: Natural frequency
- ωn = 0.6667/0.4559 = 1.462 rad/s
Step 4: K and q
- q = 2ζωn = 2 × 0.6667 = 1.333
- K = ωn² = 1.462² = 2.138
Step 5: If the 5% criterion is used
- ts = 3/(ζωn) = 6 gives ζωn = 0.5
- ωn = 0.5/0.4559 = 1.0966 rad/s
- q = 1.0, K = 1.0966² = 1.203
Conclusion
K ≈ 2.14 and q ≈ 1.33 (2% band). Check: ζ = q/(2√K) = 1.333/(2 × 1.462) = 0.456, which reproduces Mp = 20%, and 4/(ζωn) = 4/0.667 = 6 s.
Examples and data to cite
- Check by back-substitution: with K = 2.138, q = 1.333 the closed-loop poles are s = −0.667 ± j1.300; the real part fixes the settling time and the angle fixes the overshoot.
- Damped frequency ωd = ωn√(1 − ζ²) = 1.462 × 0.890 = 1.30 rad/s, giving peak time tp = π/ωd ≈ 2.42 s.
Facts to remember
- Standard second-order system: T(s) = ωn²/(s² + 2ζωn s + ωn²).
- Peak overshoot Mp = exp(−πζ/√(1 − ζ²)); depends only on ζ.
- Settling time ts ≈ 4/(ζωn) for a 2% band and ≈ 3/(ζωn) for a 5% band.
- For G(s) = K/(s(s + q)) with unity feedback, ωn = √K and ζ = q/(2√K).
- Inverting overshoot: ζ = −ln(Mp)/√(π² + ln²(Mp)).