The following circuit is given for the measurement of voltage across a 150 kΩ resistor as shown in the figure. Two voltmeters whose sensitivities are 2000 Ω/V and 30,000 Ω/V respectively are used one by one for this purpose. Both voltmeters have a range of 0 – 100 V. Calculate the reading of each voltmeter.
[Figure, described in words: the + terminal of a 200 V d.c. source connects through a 300 kΩ resistor to a node; a 150 kΩ resistor is connected from that node to the − terminal line; a two-way switch at the node connects either voltmeter V1 or voltmeter V2 across the 150 kΩ resistor.]
10 marks · directive: Calculate
The core of a good answer
Voltmeter 1 (200 kΩ) reads 44.44 V and voltmeter 2 (3 MΩ) reads 64.52 V, against a true voltage of 66.67 V; the low-sensitivity meter has a loading error of 33.3% and the high-sensitivity meter only 3.2%.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
A loading-effect problem: the voltmeter resistance (sensitivity × range) appears in parallel with the 150 kΩ resistor and changes the voltage it is meant to measure. The working must find each meter's resistance, the parallel combination and the divided voltage.
Answer outline
Introduction
Source 200 V; series resistor 300 kΩ; resistor under test 150 kΩ. Meter resistance Rm = sensitivity × full-scale range.
Step 1: True voltage (no meter)
- V = 200 × 150/(300 + 150) = 66.67 V
Step 2: Meter resistances
- Rm1 = 2000 Ω/V × 100 V = 200 kΩ
- Rm2 = 30,000 Ω/V × 100 V = 3 MΩ
Step 3: Reading of voltmeter V1
- Req1 = 150 × 200/(150 + 200) = 85.71 kΩ
- V1 = 200 × 85.71/(300 + 85.71) = 44.44 V
Step 4: Reading of voltmeter V2
- Req2 = 150 × 3000/(150 + 3000) = 142.86 kΩ
- V2 = 200 × 142.86/(300 + 142.86) = 64.52 V
Step 5: Loading errors
- Error V1 = (44.44 − 66.67)/66.67 = −33.3%
- Error V2 = (64.52 − 66.67)/66.67 = −3.2%
Conclusion
V1 reads 44.44 V and V2 reads 64.52 V. The more sensitive voltmeter (higher Ω/V) loads the high-resistance circuit far less and so reads much closer to the true 66.67 V.
Examples and data to cite
- The Thevenin resistance seen by the meter is 300 ∥ 150 = 100 kΩ, comparable to the 200 kΩ of the first meter, which is why that meter loads the circuit so heavily.
- Using Thevenin's theorem: Vth = 66.67 V, Rth = 100 kΩ, so V = 66.67 × Rm/(Rm + 100 kΩ) gives the same results.
Facts to remember
- Voltmeter sensitivity (Ω/V) is the meter-circuit resistance divided by the full-scale value.
- Voltmeter resistance Rm = S × range.
- Loading error arises because Rm is in parallel with the measured element.
- Voltage divider: V = Vs × R2/(R1 + R2).