A 1 V signal with a source resistance of Rₛ = 600 Ω is connected to an oscilloscope which has an input impedance of Rᵢ = 1 MΩ in parallel with Cᵢ = 30 pF. The coaxial cable has a capacitance C_cc = 100 pF. Calculate the oscilloscope terminal voltage (Vᵢ) when the signal frequency is 100 Hz. Also determine the frequency at which Vᵢ is 3 dB below Vₛ.
10 marks · directive: Calculate
The core of a good answer
At 100 Hz the total shunt capacitance (130 pF) has a reactance of about 12.24 MΩ, so loading is almost purely resistive and Vᵢ ≈ 0.9994 V; the upper 3 dB frequency is f = 1/(2π(Rₛ∥Rᵢ)C) ≈ 2.04 MHz.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
This is a loading problem in electronic measurement: the cable capacitance appears in parallel with the oscilloscope input, and together with the source resistance forms a low pass RC network. The method is the potential divider (or Thevenin) calculation at 100 Hz, then finding where the RC network gives a 3 dB fall (|Vᵢ/Vₛ| = 1/√2).
Answer outline
Introduction
Given Vₛ = 1 V, Rₛ = 600 Ω, Rᵢ = 1 MΩ, Cᵢ = 30 pF, C_cc = 100 pF. The cable capacitance and the input capacitance are in parallel across Rᵢ, so the load is Rᵢ in parallel with C = Cᵢ + C_cc = 130 pF.
Step 1: Total shunt capacitance and its reactance at 100 Hz
- C = 30 pF + 100 pF = 130 pF
- X_C = 1/(2π × 100 × 130 × 10⁻¹²) ≈ 12.24 MΩ
Step 2: Input impedance at 100 Hz
- Zᵢ = Rᵢ ∥ (−jX_C) = 1 MΩ ∥ (−j12.24 MΩ) ≈ 0.9967 MΩ ∠ −4.7°, i.e. almost purely resistive
Step 3: Terminal voltage
- Vᵢ = Vₛ Zᵢ/(Rₛ + Zᵢ)
- |Vᵢ| ≈ 0.9994 V (phase lag about 0.003°)
- Practically Vᵢ ≈ Vₛ Rᵢ/(Rₛ + Rᵢ) = 1 × 10⁶/1 000 600 = 0.9994 V
Step 4: Thevenin equivalent seen by the capacitance
- R_th = Rₛ ∥ Rᵢ = 600 × 10⁶/1 000 600 ≈ 599.64 Ω
- V_th = 0.9994 V; the circuit is a first order low pass with time constant τ = R_th C = 599.64 × 130 × 10⁻¹² ≈ 77.95 ns
Step 5: 3 dB frequency
- f₃dB = 1/(2π R_th C) = 1/(2π × 599.64 × 130 × 10⁻¹²) ≈ 2.04 MHz
- Since Rᵢ ≫ Rₛ this is practically 1/(2π Rₛ C) = 2.04 MHz
- Exact solution of |Vᵢ/Vₛ| = 0.7071 also gives about 2.04 MHz (2.039 MHz)
Conclusion
Vᵢ ≈ 0.9994 V at 100 Hz (loading error about 0.06 %), and Vᵢ falls 3 dB below Vₛ at about 2.04 MHz. The cable capacitance (100 pF) dominates, which is why high frequency measurements use low capacitance or compensated (×10) probes.
Examples and data to cite
- A ×10 passive probe with a compensating capacitor reduces the effective capacitive loading on the source by roughly a factor of ten.
- Rule of thumb: about 100 pF per metre is typical of ordinary coaxial cable, so even a short cable sets a megahertz range bandwidth with a 600 Ω source.
Facts to remember
- Loading: Vᵢ = Vₛ Zᵢ/(Rₛ + Zᵢ).
- Capacitive reactance X_C = 1/(2πfC).
- First order RC low pass: −3 dB (|H| = 1/√2) at f = 1/(2πRC), where R is the Thevenin resistance seen by C.
- Parallel capacitances add: C = Cᵢ + C_cc.
- Numbers recomputed in Python: X_C = 12.24 MΩ, Vᵢ = 0.99940 V, R_th = 599.64 Ω, f₃dB = 2.0417 MHz.