Pratidin
2026 · Electrical Engineering Optional Paper II · 10 marksMainsQuestion 5e

A DM system is designed to operate at 3 times the Nyquist rate for a signal with a 3 kHz bandwidth. The quantizing step size is 250 mV.
(i) Determine the maximum amplitude of a 1 kHz input sinusoid for which the delta modulator does not show slope overload.
(ii) Determine the post-filtered output signal-to-quantizing noise ratio for the signal of part (i).

10 marks · directive: Determine

Answer

The core of a good answer

With fₛ = 3 × 6 kHz = 18 kHz, slope overload is avoided for A ≤ δfₛ/(2πfₘ) = 0.25 × 18 000/(2π × 1000) ≈ 0.716 V, and the post filtered SNR is 3fₛ³/(8π²fₘ²W) ≈ 73.9, that is about 18.7 dB.

An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work

What the question asks

The question tests the two noise mechanisms of linear delta modulation: slope overload (signal slope exceeding δfₛ) and granular quantising noise. The method is to find the sampling rate, apply the slope overload condition to a sinusoid, then compute signal power over the in-band quantising noise power after the reconstruction filter.

Answer outline

Introduction

Given W = 3 kHz, Nyquist rate = 2W = 6 kHz, fₛ = 3 × 6 kHz = 18 kHz, step δ = 0.25 V, input m(t) = A cos 2πfₘt with fₘ = 1 kHz.

Step 1: Sampling rate

Step 2: Slope overload condition

Step 3: Maximum amplitude, part (i)

Step 4: Signal power

Step 5: Quantising noise after the low pass filter

Step 6: Output SNR, part (ii)

Conclusion

(i) A_max ≈ 0.716 V; (ii) post filtered SNR ≈ 73.9 ≈ 18.7 dB. Check: the closed form formula and the direct S/N calculation give the same value. The modest SNR at three times the Nyquist rate shows why DM needs heavy oversampling; SNR rises 9 dB per doubling of fₛ.

Examples and data to cite

Facts

Facts to remember

Sources used for the explanation

Write a timed answer in the app