A hollow cylinder made of insulating material surrounded by a thin metal sheath has inner and outer diameters of 4 cm and 8 cm respectively. The relative permittivity of the cylinder material is 4 and peak voltage gradient in air is 33 kV/cm. Determine the rms value of safe operating voltage of a conductor passing through the centre of the cylinder and having a diameter of 2 cm.
20 marks · directive: Determine
The core of a good answer
With an air gap from 1 cm to 2 cm radius and the εr = 4 dielectric from 2 cm to 4 cm, limiting the air gradient at the conductor surface to 33 kV/cm gives V = 33[ln 2 + (1/4) ln 2] ≈ 28.59 kV peak, so the safe operating voltage is about 20.2 kV rms.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
This is a capacitance grading or composite dielectric problem: the field in a coaxial arrangement is E = q/(2πε₀εᵣx), largest at the conductor surface, and the air (the weaker medium) breaks down first. The method fixes the charge from the allowed gradient in air at the conductor surface and integrates the field across both layers to get the voltage.
Answer outline
Introduction
Conductor radius r = 1 cm; air from 1 cm to 2 cm (εr = 1); insulating cylinder from R₁ = 2 cm to R₂ = 4 cm (εr = 4); sheath at 4 cm earthed. Maximum allowed gradient in air g_max = 33 kV/cm (peak), occurring at x = r.
Step 1: Field in each layer
- E(x) = q/(2πε₀εᵣx), where q is the charge per unit length
- In air: E = q/(2πε₀x); in the dielectric: E = q/(2πε₀ × 4 × x)
Step 2: Fix the charge from the air gradient
- At x = 1 cm in air: q/(2πε₀ × 1) = 33 kV/cm
- So q/(2πε₀) = 33 kV (with x in cm)
Step 3: Voltage across the air gap
- V_air = (q/2πε₀) ln(2/1) = 33 × 0.6931 = 22.87 kV
Step 4: Voltage across the insulating cylinder
- V_ins = (q/2πε₀ × 4) ln(4/2) = (33/4) × 0.6931 = 5.72 kV
Step 5: Total peak voltage and rms value
- V_peak = 22.87 + 5.72 = 28.59 kV
- V_rms = 28.59/√2 ≈ 20.22 kV
Step 6: Check of the dielectric
- Maximum gradient in the insulating material at x = 2 cm = 33/(4 × 2) = 4.125 kV/cm, far below the air gradient, so the air gap is the limiting layer
Conclusion
The safe operating voltage is about 28.6 kV peak, i.e. about 20.2 kV rms. Most of the voltage (about 80 %) appears across the 1 cm air gap because its permittivity is lowest.
Examples and data to cite
- This arrangement places the lowest permittivity medium (air) next to the conductor, where the field is strongest, so about 80 % of the voltage (22.87 of 28.59 kV) appears across the 1 cm air gap.
- The dielectric strength of air is about 3 MV/m (30 kV/cm) and depends on humidity, pressure and electrode geometry, which is the same order as the 33 kV/cm peak gradient given here.
Facts to remember
- Field between coaxial cylinders: E = q/(2πε₀εᵣx); maximum at the inner surface.
- Voltage across a layer from a to b: V = (q/2πε₀εᵣ) ln(b/a).
- In layered dielectrics the electric flux density D is continuous, so the gradient is inversely proportional to εᵣ.
- rms = peak/√2 for a sinusoidal voltage.
- Numbers recomputed in Python: V_peak = 28.592 kV, V_rms = 20.218 kV.