A production process is monitored using X̄ and R charts. Fifteen subgroups of size n = 5 were inspected. The grand mean X̄ = 48·6 mm and the mean range R̄ = 4·2 mm. Use the following control chart constants :
A₂ = 0·577, D₃ = 0, D₄ = 2·114, where
A₂ is for the X̄ chart, D₃ and D₄ are for the R chart
(i) Compute the upper and lower control limits for both the X̄ chart and the R chart.
(ii) A separate attribute inspection of 20 lots of 200 units each found a total of 184 defective units. Construct a p-chart : compute p̄ , upper control limit (UCL-p) and lower control limit (LCL-p).
10 marks · directive: Compute
Answer
The core of a good answer
X̄ chart: CL 48·6, UCL 51·02, LCL 46·18 mm; R chart: CL 4·2, UCL 8·88, LCL 0 mm; p-chart: p̄ = 184/4000 = 0·046, UCL = 0·0904 and LCL = 0·0016.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
Shewhart control limits. For variables: X̄ limits X̿ ± A₂R̄, R limits D₃R̄ and D₄R̄. For attributes with constant sample size: p̄ ± 3√(p̄(1 − p̄)/n).
Answer outline
Introduction
Variables data: 15 subgroups of n = 5, X̿ = 48·6 mm, R̄ = 4·2 mm. Attribute data: 20 lots × 200 = 4000 units inspected, 184 defective.
Step 1: X̄ chart
- A₂R̄ = 0·577 × 4·2 = 2·423 mm
- UCL = 48·6 + 2·423 = 51·02 mm
- LCL = 48·6 − 2·423 = 46·18 mm
Step 2: R chart
- UCL = D₄R̄ = 2·114 × 4·2 = 8·88 mm
- LCL = D₃R̄ = 0
- CL = 4·2 mm
Step 3: p̄
- p̄ = 184/(20 × 200) = 0·046 (4·6%)
Step 4: p-chart limits
- σ_p = √(0·046 × 0·954/200) = 0·01481
- UCL = 0·046 + 3(0·01481) = 0·0904
- LCL = 0·046 − 0·0444 = 0·0016 (positive)
- In defectives per lot of 200: CL 9·2, UCL 18·1, LCL 0·3
Step 5: Use
- Plot each subgroup mean and range and each lot's fraction defective; points outside limits or non-random patterns signal assignable causes
Conclusion
X̄: 46·18 to 51·02 mm; R: 0 to 8·88 mm; p: 0·0016 to 0·0904 about p̄ = 0·046. The R chart should be checked in control first, since the X̄ limits use R̄. (Recomputed in Python.)
Examples and data to cite
- Machined shaft diameters can be tracked with X̄ and R charts, and go/no-go inspection results with p-charts.
Facts
Facts to remember
- X̄ chart limits: X̿ ± A₂R̄; R chart: D₃R̄ and D₄R̄ (centre line R̄).
- Tabulated factors for n = 5: A₂ = 0·577, D₃ = 0, D₄ = 2·115 (the paper prints 2·114, which is used here).
- p-chart limits: p̄ ± 3√(p̄(1 − p̄)/n), with p̄ = total defectives/total inspected.