Determine the heat transfer through the composite wall shown in the figure below. Take the thermal conductivities of A, B, C, D and E as 50, 10, 8, 20 and 25 W/m-K, respectively and assume one-dimensional heat transfer :
[Figure, described in words: a composite wall drawn in perspective, with T₁ = 800 °C and an arrow Q entering the left face and T₂ = 200 °C on the right face, which is labelled A = 1 m². From left to right the layers are: A, 5 cm thick, over the full height; then B above C, side by side in the same 10 cm thick layer, separated by a horizontal line drawn at mid-height (the areas of B and C are not marked); then D, 10 cm thick, over the full height; then E, 5 cm thick, over the full height.]
10 marks · directive: Determine
The core of a good answer
Assuming B and C each occupy 0.5 m² (the figure draws them as equal halves but marks no areas) and treating them as parallel resistances in series with A, D and E, the total resistance is 0.001 + 0.01111 + 0.005 + 0.002 = 0.01911 K/W, so Q = (800 − 200)/0.01911 ≈ 31,395 W ≈ 31.4 kW.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
An electrical-analogy problem. With one-dimensional flow, layers in the flow direction are series resistances L/(kA) and layers side by side are parallel resistances. Build the network, add resistances and divide the overall temperature difference.
Answer outline
Introduction
Assumptions: steady one-dimensional conduction, constant k, perfect contact, B and C are taken to occupy equal halves of the 1 m² face (0.5 m² each), since the dividing line is drawn at mid-height and their areas are not marked; state this assumption.
Step 1: Individual resistances R = L/(kA)
- R_A = 0.05/(50 × 1) = 0.001 K/W
- R_B = 0.10/(10 × 0.5) = 0.020 K/W
- R_C = 0.10/(8 × 0.5) = 0.025 K/W
- R_D = 0.10/(20 × 1) = 0.005 K/W
- R_E = 0.05/(25 × 1) = 0.002 K/W
Step 2: Parallel pair B and C
- B and C carry heat side by side across the same temperature difference ΔT, so Q_BC = ΔT/R_B + ΔT/R_C
- 1/R_BC = 1/0.020 + 1/0.025 = 50 + 40 = 90, so R_BC = 0.01111 K/W
Step 3: Total resistance and heat flow
- R_total = 0.001 + 0.01111 + 0.005 + 0.002 = 0.01911 K/W
- Q = (T₁ − T₂)/R_total = 600/0.01911 = 31,395 W ≈ 31.4 kW
Step 4: Interface temperatures (check)
- After A: 800 − 31,395 × 0.001 = 768.6 °C
- After B/C: 768.6 − 31,395 × 0.01111 = 419.8 °C
- After D: 419.8 − 31,395 × 0.005 = 262.8 °C; after E: 262.8 − 62.8 = 200 °C
Conclusion
Heat transfer ≈ 31.4 kW through the 1 m² wall; the B/C layer carries the largest share of the resistance (58%). The one-dimensional assumption ignores lateral flow between B and C. Recomputed in Python.
Facts to remember
- Plane wall conduction resistance R = L/(kA).
- Series resistances add; for layers side by side the heat flows add, so 1/R = Σ 1/Rᵢ.
- Q = ΔT_overall/ΣR.