Consider a large plane wall of thickness 0.25 m, having thermal conductivity 3 W/m-°C and surface area 10 m². The left side of the wall is subjected to a net heat flux of 750 W/m². The surface temperature of the left side of the wall is 90 °C. Assuming constant thermal conductivity and no heat generation in the wall, express the differential equation and boundary conditions for steady one-dimensional heat conduction through the wall. Also, obtain a relation for the variation of temperature in the wall by solving the differential equation and find the temperature of the right side of the wall.
10 marks · directive: Express
The core of a good answer
d²T/dx² = 0 with −k dT/dx|ₓ₌₀ = 750 W/m² and T(0) = 90 °C gives T(x) = 90 − 250x (x in m, T in °C), so the right face (x = 0.25 m) is at 27.5 °C; the heat flow is 7.5 kW.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
Set up and solve the one-dimensional heat conduction equation. Both boundary conditions are at the left face (a specified heat flux and a specified temperature), which is enough to fix the two constants of integration.
Answer outline
Introduction
Take x = 0 at the left face and x = L = 0.25 m at the right face; k = 3 W/m-°C, A = 10 m², q₀ = 750 W/m², T(0) = 90 °C.
Step 1: Differential equation
- General conduction equation with constant k, steady, no generation, one-dimensional: d²T/dx² = 0
Step 2: Boundary conditions
- Heat flux at x = 0: −k (dT/dx)|ₓ₌₀ = q₀ = 750 W/m²
- Temperature at x = 0: T(0) = T₁ = 90 °C
Step 3: Solve
- Integrating twice: T(x) = C₁x + C₂
- From the flux condition: −kC₁ = q₀, so C₁ = −q₀/k = −750/3 = −250 °C/m
- From T(0) = 90: C₂ = 90 °C
- T(x) = −(q₀/k)x + T₁ = 90 − 250x
Step 4: Right-side temperature and heat flow
- T(L) = 90 − 250 × 0.25 = 27.5 °C
- Q = q₀A = 750 × 10 = 7500 W, constant through the wall
Conclusion
The temperature falls linearly from 90 °C to 27.5 °C; check: Q = kA(T₁ − T₂)/L = 3 × 10 × 62.5/0.25 = 7500 W, equal to q₀A.
Facts to remember
- Fourier's law q = −k dT/dx.
- Steady one-dimensional conduction with constant k and no generation: d²T/dx² = 0.
- Specified heat flux boundary condition: −k dT/dx = q₀ at the surface.
- Plane wall: Q = kA(T₁ − T₂)/L.