Describe the behaviour of steam flow in a convergent nozzle when it is operated at—
(i) design pressure ratio;
(ii) pressure ratio higher than the design value;
(iii) pressure ratio lower than the design value.

10 marks · directive: Describe

Answer

The core of a good answer

A convergent nozzle is designed to expand to the critical pressure at exit: at the design pressure ratio the exit velocity is sonic and the flow is choked at maximum discharge; at a higher pressure ratio (back pressure above critical) the exit is subsonic, exit pressure equals back pressure and discharge is less; at a lower ratio the flow stays choked, discharge does not increase, and the steam leaves under-expanded and expands further outside the nozzle through expansion waves, wasting energy.

An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work

What the question asks

Describe the three regimes of a convergent nozzle in terms of the ratio of back pressure to inlet (stagnation) pressure, with the mass flow against pressure ratio curve and the pressure distribution along the nozzle.

Answer outline

Introduction

Let p₁ be inlet pressure, p_b back pressure and p_c the critical pressure. For a gas expanding with index n, p_c/p₁ = (2/(n + 1))^(n/(n − 1)); for dry air (n = γ = 1.4) this is 0.528. The design pressure ratio of a convergent nozzle is this critical ratio.

(i) At design pressure ratio (p_b/p₁ = critical)

(ii) Pressure ratio higher than design (p_b/p₁ > critical)

(iii) Pressure ratio lower than design (p_b/p₁ < critical)

Conclusion

Below the critical pressure ratio a convergent nozzle is choked: lowering back pressure only adds external expansion losses,.