Pratidin
2026 · Mechanical Engineering Optional Paper II · 20 marksMainsQuestion 7a

In a cogeneration plant, the net power output is 6 MW and the heating load is 1.5 MW. Steam is generated at 40 bar and 500 °C, and is expanded isentropically through a turbine to a condenser at 0.1 bar. The heating load is supplied by extracting steam from the turbine at 2 bar, which is condensed in a process heater to saturated liquid at 2 bar and then pumped back to the boiler. Draw the schematic and T-s diagram. Determine (i) the steam generation capacity (in kg/s) of the boiler and (ii) mass flow rate (in kg/s) of the steam through the heating load.
The steam properties at 40 bar, 500 °C are h = 3445.21 kJ/kg, s = 7.09 kJ/kg-K.
Use steam tables given at the end to get other properties.

20 marks · directive: Determine

Answer

The core of a good answer

Isentropic expansion gives h = 2692.1 kJ/kg at 2 bar (x = 0.9934) and 2246.4 kJ/kg at 0.1 bar (x = 0.8587); the process heater needs 1500/(2692.1 − 504.68) = 0.686 kg/s, and the net power balance including both feed pumps gives a boiler steam generation of about 5.28 kg/s.

An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work

What the question asks

A cogeneration (extraction) Rankine cycle. Fix the turbine states from s = constant with the given steam tables, get the extraction flow from the heating load, then solve the net power equation (turbine work of both streams minus the two pump works) for the total steam flow.

Answer outline

Introduction

State 1: 40 bar, 500 °C, h₁ = 3445.21 kJ/kg, s₁ = 7.09 kJ/kg-K. Extraction at 2 bar (200 kPa): h_f = 504.68, h_fg = 2201.96, s_f = 1.5300, s_fg = 5.5970, v_f = 0.001061. Condenser 0.1 bar (10 kPa): h_f = 191.81, h_fg = 2392.82, s_f = 0.6492, s_fg = 7.5010, v_f = 0.001010. Schematic: boiler, turbine with bleed at 2 bar to process heater, remainder to condenser; condensate pump and process-heater pump both deliver to the boiler. T-s: 1 to 2 (2 bar) to 3 (0.1 bar) on one vertical line; liquid states at 0.1 and 2 bar pumped to 40 bar.

Step 1: Extraction state (2 bar)

Step 2: Condenser inlet (0.1 bar)

Step 3: (ii) Steam to heating load

Step 4: Pump works

Step 5: (i) Boiler steam generation

Conclusion

Boiler steam generation ≈ 5.28 kg/s and steam through the heating load ≈ 0.686 kg/s. Recomputed in Python with the steam table values printed with the paper.

Examples and data to cite

Facts

Facts to remember

Sources used for the explanation

Write a timed answer in the app