A chimney of 35 m height is discharging the flue gases at 300 °C, when the ambient temperature is 25 °C. The quantity of air supplied is 16 kg per kg of fuel burnt. Determine the—
(i) draught produced in mm of water;
(ii) equivalent draught in metres of hot gas column;
(iii) efficiency of the chimney, if the minimum temperature of artificial draught is 120 °C and the mean specific heat of hot flue gases is 1.005 kJ/kg-K;
(iv) percentage of heat spent in natural draught system, if the net calorific value of the fuel is 33000 kJ/kg.
10 marks · directive: Determine
The core of a good answer
With ρ_air = 353/T_a and ρ_gas = (353/T_g)(m + 1)/m from the ideal gas law, (i) draught = H(ρ_a − ρ_g) = 18.5 mm of water; (ii) equivalent hot gas column H₁ = H[(m/(m + 1))(T_g/T_a) − 1] = 28.3 m; (iv) heat spent = 17 × 1.005 × 180/33,000 = 9.3% of the calorific value. Part (iii), chimney efficiency, is left out because no standard source for its definition could be opened.
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
Natural draught calculations. Write the densities of the cold air column and the hot gas column from the ideal gas law, find the pressure difference (draught) in mm of water and as an equivalent height of hot gas, and find the extra heat carried away by discharging at 300 °C instead of the 120 °C possible with artificial draught. The answer to part (iii) (chimney efficiency) is left out: no standard source for its definition could be opened.
Answer outline
Introduction
H = 35 m, T_g = 573.15 K, T_a = 298.15 K, m = 16 kg air/kg fuel (so m + 1 = 17 kg gas), c_p = 1.005 kJ/kg-K, T_art = 120 °C, net CV = 33,000 kJ/kg. Air density at 1 atm: ρ = 101.325/(0.287T) ≈ 353/T kg/m³; flue gas taken as having the same volume as the air at the same temperature.
Step 1: Densities
- ρ_a = 353/298.15 = 1.184 kg/m³
- ρ_g = (353/573.15) × 17/16 = 0.654 kg/m³
Step 2: (i) Draught in mm of water
- h_w = H(ρ_a − ρ_g) = 35 × (1.184 − 0.654) = 18.5 mm of water (1 kg/m² of pressure difference = 1 mm of water)
Step 3: (ii) Equivalent hot gas column
- H₁ = H(ρ_a/ρ_g − 1) = 35 × [(16/17)(573.15/298.15) − 1] = 35 × 0.809 = 28.3 m
Step 4: (iv) Heat spent on natural draught
- Extra heat per kg fuel = (m + 1)c_p(T_g − T_art) = 17 × 1.005 × 180 = 3075 kJ/kg
- Percentage = 3075/33,000 × 100 = 9.32%
Conclusion
Draught ≈ 18.5 mm of water, equivalent to 28.3 m of hot gas, and about 9.3% of the fuel's heat is carried away to create natural draught. Recomputed in Python.
Examples and data to cite
- Fan-assisted forced draught, introduced in the early 20th century, removed the industrial chimney's original function of creating draught.
Facts to remember
- Ideal gas density ρ = P/(RT); for air at 101.325 kPa, ρ = 101.325/(0.287T) ≈ 353/T kg/m³.
- Draught = H(ρ_a − ρ_g) kg/m², numerically equal to mm of water.
- Hot gas column H₁ = H(ρ_a/ρ_g − 1) = H[(m/(m + 1))(T_g/T_a) − 1].
- Stack draught arises from the temperature difference between the flue gas column and the outside air.