(i) Why is the relaxation process so important in nuclear magnetic resonance (NMR)?
(ii) Why are ¹²C and ¹⁶C nuclei not suitable for the study of NMR?
15 marks · directive: Explain
The core of a good answer
Relaxation (spin-lattice T₁ and spin-spin T₂) restores the small Boltzmann excess of nuclei in the lower Zeeman level; without it the RF field would equalise the populations and the signal would saturate and vanish, and T₁ and T₂ also set line widths, repetition rates and MRI contrast. ¹²C and ¹⁶C are even-even nuclei with nuclear spin I = 0, so they have no magnetic moment and no Zeeman splitting, hence no NMR signal (¹³C, with I = 1/2, is used instead).
An outline written by upsc.help, not an official UPSC answer; every fact checked by a separate review. How we work
What the question asks
Part (i) (10 marks) needs the population argument, definitions of T₁ and T₂ and their uses. Part (ii) (5 marks) needs the condition for NMR activity (I ≠ 0) and the even-even rule. The paper prints ¹⁶C; ¹⁶O (also even-even, I = 0) may have been intended, and the same reason applies to both.
Answer outline
Introduction
In a field B₀ a spin-1/2 nucleus has two levels separated by ΔE = γħB₀. The population excess in the lower level is tiny (Boltzmann factor e^(−ΔE/kT) close to 1), and the net absorption depends on it.
(i) Saturation and the need for relaxation
- The RF field induces upward and downward transitions with equal probability
- Net absorption is proportional to the population difference; continued irradiation drives it to zero (saturation)
- Relaxation returns energy to the surroundings and restores the Boltzmann difference, so the signal can be sustained or repeated
(i) T₁ and T₂
- T₁ (spin-lattice, longitudinal): time for M_z to recover to equilibrium; energy transferred to the lattice
- T₂ (spin-spin, transverse): time for the transverse magnetisation to dephase; T₁ is usually longer than T₂
- Bloch equations describe both
(i) Practical importance
- T₂ governs the width of the resonance lines: very short T₂ (solids) gives broad lines, long T₂ (liquids) gives sharp lines
- T₁ fixes how fast pulses can be repeated in pulsed (Fourier transform) NMR
- Different tissues have different T₁ and T₂, the basis of MRI contrast
(ii) Condition for NMR
- NMR needs a magnetic moment μ = γħI, so I ≠ 0
- Even Z and even N: nucleons pair to give ground-state spin I = 0
- ¹²C (Z = 6, N = 6) and ¹⁶C (Z = 6, N = 10) are even-even, so I = 0, μ = 0, no Zeeman levels, no resonance
- Carbon NMR uses ¹³C (I = 1/2, natural abundance about 1.1%)
Conclusion
Relaxation is what keeps NMR from saturating and makes T₁ and T₂ measurable information; spin-zero even-even nuclei such as ¹²C and ¹⁶C (or ¹⁶O) are NMR-silent.
Facts to remember
- Larmor or resonance condition: ω₀ = γB₀.
- T₁: spin-lattice relaxation; T₂: spin-spin relaxation; T₁ is usually longer than T₂.
- Nuclei with even numbers of both protons and neutrons have zero spin and give no NMR signal.
- ¹³C has I = 1/2 and natural abundance of about 1.1%.